Files
ROMFASTSQL/proxmox/vm201-windows11.md
Marius 90d77704d6 Reorganize Proxmox documentation with clear structure and VM/LXC mapping
## Changes

### Documentation Reorganization
- **README.md**: Complete restructure with logical sections
  - Infrastructure General (proxmox-ssh-guide.md)
  - LXC Containers (oracle-database-lxc108.md)
  - Virtual Machines (vm201-*.md)
  - Cluster-Wide Resources (cluster-ha-monitor.sh, ups/)
  - Archived/Decommissioned (archived-vm107-monitor.sh)
  - Added quick navigation "Am nevoie să..." section
  - Added recommended workflows
  - Added complete directory structure map

- **proxmox-ssh-guide.md**: Added documentation references section
  - Clear links to all related documentation
  - When to use each document
  - Quick start snippets for each resource

### File Renames for Clarity
- `certificat-letsencrypt-iis.md` → `vm201-certificat-letsencrypt-iis.md`
- `troubleshooting-vm201-backup-nfs.md` → `vm201-troubleshooting-backup-nfs.md`
- `ha-monitor.sh` → `cluster-ha-monitor.sh`
- `vm107-monitor.sh` → `archived-vm107-monitor.sh`

### New Documentation
- **vm201-windows11.md**: Complete VM 201 documentation
  - Hardware configuration
  - Installed services (IIS, SQL*Plus, WinNUT, RDP)
  - Network configuration
  - Backup and recovery procedures
  - Common troubleshooting

## Benefits
- Clear naming convention: VM/LXC/Cluster prefixes
- Central index in README.md with navigation
- Cross-references between documents
- Complete VM 201 documentation suite
- Clear archival of decommissioned resources

🤖 Generated with [Claude Code](https://claude.com/claude-code)

Co-Authored-By: Claude <noreply@anthropic.com>
2025-11-19 13:43:44 +02:00

408 lines
11 KiB
Markdown

# VM 201 - Windows 11 (roacentral)
## 📌 Informații Generale
- **VMID:** 201
- **Nume:** roacentral
- **OS:** Windows 11 Pro (24H2)
- **Host Proxmox:** pvemini (10.0.20.201)
- **Storage:** local-zfs (ZFS pool)
- **Status:** Running (onboot: enabled)
- **Rol:** Client aplicații Windows, SQL*Plus client, Reverse proxy IIS, Monitorizare UPS
---
## 💻 Configurație Hardware
### Resurse Alocate
- **CPU:** 2 cores (Intel CPU host)
- **RAM:** 4 GB
- **Storage:** 500 GB (local-zfs)
- **Network:** virtio (DHCP)
- **Display:** VirtIO-GPU (spice)
### Storage Details
```bash
# Verificare disk usage
ssh root@10.0.20.201 "qm config 201 | grep scsi"
# Output:
# scsi0: local-zfs:vm-201-disk-0,size=500G
```
### Network Configuration
- **Interface:** net0 - virtio bridge=vmbr0
- **IP Assignment:** DHCP (managed by network DHCP server)
- **MAC Address:** Auto-generated by Proxmox
- **Hostname:** roacentral
---
## 🎯 Rol și Utilizare
### Funcții Principale
#### 1. Client Aplicații Windows
- **Aplicații ROMFAST** - Client desktop pentru aplicații contabilitate
- **SQL*Plus Client** - Conexiuni la Oracle Database (LXC 108)
- **Management Tools** - Administrare Windows pentru infrastructură
#### 2. Reverse Proxy IIS
- **IIS (Internet Information Services)** - Reverse proxy către servicii interne
- **SSL/TLS Termination** - Certificate Let's Encrypt pentru domenii externe
- **SNI (Server Name Indication)** - Multiple certificate pe același IP
- **Domenii gestionate:**
- roa.romfast.ro
- dokploy.romfast.ro
- gitea.romfast.ro
**Documentație:** Vezi `vm201-certificat-letsencrypt-iis.md`
#### 3. Monitorizare UPS
- **WinNUT Client** - Monitorizare vizuală status UPS în timp real
- **Server NUT:** 10.0.20.201:3493 (pvemini)
- **UPS:** nutdev1 (INNO TECH USB UPS)
- **Polling:** 15 secunde
**Documentație:** Vezi `ups/docs/INSTALARE-WINNUT.md`
---
## 🔧 Servicii Instalate
### Software Principal
#### 1. Oracle SQL*Plus Client
- **Versiune:** Oracle Instant Client (compatible cu Oracle XE 21c)
- **Conexiuni:**
```cmd
sqlplus sys/romfastsoft@10.0.20.121:1521/roa as sysdba
sqlplus CONTAFIN_ORACLE/OraclePass123@10.0.20.121:1521/roa
```
- **JDBC Driver:** oracle.jdbc.driver.OracleDriver
- **Connection String:** `jdbc:oracle:thin:@10.0.20.121:1521/roa`
#### 2. IIS (Internet Information Services)
- **Versiune:** IIS 10.0 (Windows 11)
- **Features Enabled:**
- Web Server (IIS)
- ASP.NET 4.8
- WebSockets Protocol
- HTTP Redirect
- URL Rewrite Module
- **Sites:**
- Default Web Site (roa.romfast.ro)
- Dokploy (dokploy.romfast.ro)
- Gitea (gitea.romfast.ro)
**Configurare SSL:** Vezi `vm201-certificat-letsencrypt-iis.md`
#### 3. Win-ACME
- **Versiune:** v2.2.9.1701
- **Locație:** `C:\Tools\win-acme\`
- **Scop:** Certificate Let's Encrypt automate
- **Task Scheduler:** Reînnoire automată zilnică (verificare)
- **Certificate Storage:** LocalMachine\My (Certificate Store)
#### 4. WinNUT Client
- **Versiune:** WinNUT-Client-2.x
- **Configurare:**
- Server: 10.0.20.201
- Port: 3493
- UPS: nutdev1
- User: admin
- Password: parola99
- Polling: 15s
- **Scop:** Monitorizare vizuală UPS (NU controlează shutdown)
#### 5. Remote Desktop
- **RDP Enabled:** Da
- **Port:** 3389 (default)
- **Network Level Authentication:** Enabled
- **Acces:** `mstsc /v:roacentral` (din rețea locală)
---
## 🌐 Configurare Rețea
### Network Settings
- **Adapter Type:** virtio (paravirtualized)
- **Bridge:** vmbr0 (Proxmox bridge)
- **IP Assignment:** DHCP
- **DNS:** Managed by DHCP
- **Hostname:** roacentral
### Firewall Rules (Windows Firewall)
```powershell
# Permite RDP
Enable-NetFirewallRule -DisplayGroup "Remote Desktop"
# Permite IIS HTTP/HTTPS
New-NetFirewallRule -DisplayName "IIS HTTP" -Direction Inbound -Protocol TCP -LocalPort 80 -Action Allow
New-NetFirewallRule -DisplayName "IIS HTTPS" -Direction Inbound -Protocol TCP -LocalPort 443 -Action Allow
# Permite ping (ICMP)
Enable-NetFirewallRule -DisplayName "File and Printer Sharing (Echo Request - ICMPv4-In)"
```
### Network Troubleshooting
```powershell
# Verificare IP și gateway
ipconfig /all
# Test conectivitate Oracle
Test-NetConnection -ComputerName 10.0.20.121 -Port 1521
# Test conectivitate NUT server
Test-NetConnection -ComputerName 10.0.20.201 -Port 3493
# Flush DNS cache
ipconfig /flushdns
```
---
## 💾 Backup și Recovery
### Backup Job Proxmox
- **Frecvență:** Zilnic la 02:00 (part of backup job-10dfdb0d-fb47)
- **Storage:** backup (`/mnt/backup` pe pvemini)
- **Tip:** Snapshot (Proxmox VZDump)
- **Retention:** keep-all=1 (păstrează toate backup-urile)
- **Format:** `.vma.zst` (compressed)
### Backup Manual
```bash
# Backup complet VM 201
ssh root@10.0.20.201 "vzdump 201 --storage backup --mode snapshot --compress zstd"
# Verificare backup-uri existente
ssh root@10.0.20.201 "ls -lh /mnt/backup/dump/vzdump-qemu-201-*.vma.zst"
```
### Recovery VM 201
```bash
# Listare backup-uri disponibile
ssh root@10.0.20.201 "pvesm list backup | grep 201"
# Restore din backup (creează VM nou cu VMID 202)
ssh root@10.0.20.201 "qmrestore /mnt/backup/dump/vzdump-qemu-201-YYYY_MM_DD-HH_MM_SS.vma.zst 202"
# Sau restore peste VM existent (ATENȚIE: șterge VM curent)
ssh root@10.0.20.201 "qm stop 201 && qmrestore /mnt/backup/dump/vzdump-qemu-201-*.vma.zst 201 --force"
```
---
## 🚨 Troubleshooting Comun
### VM Nu Pornește
**Diagnostic:**
```bash
# Status VM
ssh root@10.0.20.201 "qm status 201"
# Verificare lock-uri
ssh root@10.0.20.201 "qm config 201 | grep lock"
# Verificare proces KVM
ssh root@10.0.20.201 "ps aux | grep 'qm\|kvm' | grep 201"
```
**Rezolvare:**
```bash
# Unlock VM (dacă are lock de backup)
ssh root@10.0.20.201 "qm unlock 201"
# Start VM
ssh root@10.0.20.201 "qm start 201"
```
**Referință:** Vezi `vm201-troubleshooting-backup-nfs.md` pentru incident similar
### VM Locked după Backup Eșuat
**Verificare:**
```bash
ssh root@10.0.20.201 "qm config 201 | grep lock"
```
**Rezolvare:**
```bash
ssh root@10.0.20.201 "qm unlock 201"
```
**Documentație completă:** `vm201-troubleshooting-backup-nfs.md`
### RDP Nu Funcționează
**Verificare din Proxmox:**
```bash
# Status VM
ssh root@10.0.20.201 "qm status 201"
# Verificare port 3389 (din alt sistem)
nc -zv <VM_IP> 3389
```
**Rezolvare în Windows:**
```powershell
# Enable RDP
Set-ItemProperty -Path 'HKLM:\System\CurrentControlSet\Control\Terminal Server' -Name "fDenyTSConnections" -Value 0
# Restart serviciu
Restart-Service TermService -Force
# Verificare firewall
Enable-NetFirewallRule -DisplayGroup "Remote Desktop"
```
### Certificate SSL Expirate
**Verificare:**
```powershell
# Listare certificate Let's Encrypt
Get-ChildItem Cert:\LocalMachine\My | Where-Object {
$_.Issuer -like "*Let's Encrypt*" -and $_.NotAfter -gt (Get-Date)
} | Select-Object Subject, NotAfter, Thumbprint
```
**Reînnoire:**
```powershell
cd C:\Tools\win-acme
.\wacs.exe --renew --force
iisreset
```
**Documentație completă:** `vm201-certificat-letsencrypt-iis.md`
---
## 🔗 Comenzi Rapide Proxmox
### Gestiune VM 201
```bash
# Start VM
ssh root@10.0.20.201 "qm start 201"
# Stop VM (graceful)
ssh root@10.0.20.201 "qm stop 201"
# Force stop VM (SIGKILL)
ssh root@10.0.20.201 "qm stop 201 --skiplock"
# Restart VM
ssh root@10.0.20.201 "qm restart 201"
# Status VM
ssh root@10.0.20.201 "qm status 201"
# Configurație VM
ssh root@10.0.20.201 "qm config 201"
# Modificare RAM/CPU
ssh root@10.0.20.201 "qm set 201 --memory 8192 --cores 4"
# Console VM (VNC prin Proxmox GUI)
# Acces: https://10.0.20.201:8006 -> VM 201 -> Console
```
### Backup și Snapshot
```bash
# Backup manual
ssh root@10.0.20.201 "vzdump 201 --storage backup --mode snapshot --compress zstd"
# Creare snapshot
ssh root@10.0.20.201 "qm snapshot 201 pre-update-snapshot"
# Listare snapshot-uri
ssh root@10.0.20.201 "qm listsnapshot 201"
# Rollback la snapshot
ssh root@10.0.20.201 "qm rollback 201 pre-update-snapshot"
# Ștergere snapshot
ssh root@10.0.20.201 "qm delsnapshot 201 pre-update-snapshot"
```
---
## 📖 Documentație Asociată
### Documentație VM 201 Specifică
- **SSL Certificates IIS:** `vm201-certificat-letsencrypt-iis.md`
- **Troubleshooting Incident 2025-10-08:** `vm201-troubleshooting-backup-nfs.md`
### Documentație Infrastructură Generală
- **Proxmox Cluster General:** `proxmox-ssh-guide.md`
- **Oracle Database (LXC 108):** `oracle-database-lxc108.md`
### Documentație UPS
- **Instalare WinNUT Client:** `ups/docs/INSTALARE-WINNUT.md`
- **Sistem UPS Cluster:** `ups/README.md`
---
## 📝 Notițe Importante
### Considerații Performanță
- VM 201 rulează pe **local-zfs** pentru performanță optimă (ZFS pool)
- **Snapshot-urile** sunt rapide (ZFS COW - copy-on-write)
- **Backup-urile** nu afectează performanța VM (Proxmox snapshot)
### Securitate
- **RDP:** Expus doar în rețea locală (10.0.20.0/24)
- **Certificate SSL:** Reînnoire automată Let's Encrypt (90 zile)
- **Firewall:** Windows Firewall active cu reguli restrictive
- **Updates:** Windows Update enabled (automatic patches)
### Dependențe
- **Oracle Database:** LXC 108 (10.0.20.121:1521) - SQL*Plus client
- **UPS Monitoring:** NUT server pe pvemini (10.0.20.201:3493)
- **Reverse Proxy Targets:**
- Dokploy: 10.0.20.167:3000
- Gitea: 10.0.20.165:3000
- Portainer: 10.0.20.170:9443
### High Availability
- **HA Status:** Enabled (managed by pve-ha-crm)
- **Priority:** Normal
- **Autostart:** Enabled (onboot: 1)
- **Recovery:** Automatic VM migration în caz de node failure
**Troubleshooting HA:** Vezi `vm201-troubleshooting-backup-nfs.md` → "VM 201 - HA Error"
---
## 🎯 Flux de Lucru Recomandat
### Pentru Configurare Nouă
1. **Citește acest document** pentru context general
2. **Pentru SSL/IIS:** Vezi `vm201-certificat-letsencrypt-iis.md`
3. **Testează configurația**
4. **Creează snapshot** înainte de modificări majore
5. **Documentează** schimbările în fișiere relevante
### Pentru Probleme
1. **Verifică status VM:** `qm status 201`
2. **Verifică lock-uri:** `qm config 201 | grep lock`
3. **Consultă troubleshooting:** `vm201-troubleshooting-backup-nfs.md`
4. **Verifică logs:** Windows Event Viewer sau Proxmox logs
5. **Documentează problema** și rezolvarea pentru viitor
### Pentru Mentenanță
1. **Creează snapshot** înainte de update-uri: `qm snapshot 201 pre-maintenance`
2. **Verifică backup recent:** Ultimul backup în `/mnt/backup/dump/`
3. **Aplică update-uri** Windows Update sau IIS
4. **Testează funcționalitate** (RDP, IIS, SQL*Plus)
5. **Șterge snapshot** dacă totul funcționează: `qm delsnapshot 201 pre-maintenance`
---
**Ultima actualizare:** 2025-11-19
**Autor:** Marius Mutu
**Proiect:** ROMFASTSQL - VM 201 Documentation