Commit Graph

4 Commits

Author SHA1 Message Date
Claude Agent
1df533edba docs(lxc110): incident DNS/OOM 2026-07-31 + zram pe pve1 + limite TTS
LXC 110 (moltbot) a picat dupa un OOM local containerului urmat de reboot:
tailscaled a ramas delogat, iar containerul mostenea resolv.conf-ul Tailscale
de la host-ul pve1 (doar MagicDNS 100.100.100.100) -> rezolutie DNS zero desi
L3 era functional -> echo-core in crash-loop pe telegram.error.TimedOut.

Fixuri aplicate:
- pct set 110 --nameserver '10.0.20.1 1.1.1.1' (elimina dependenta de Tailscale)
- zram-tools pe pve1 (8G zstd, prio 100) - `swap: 4096` din config era fictiv,
  host-ul nu avea niciun swap; root pe ZFS deci zram, nu swapfile
- MemoryHigh/MemoryMax pe pocket-tts + supertonic-tts - toate serviciile user
  rulau cu limite `infinity`, de unde OOM-uri recurente (Apr 25, May 28 x4)
  cu victime aleatorii alese dupa oom_score_adj

Documentatie:
- nou post-mortem in cluster/incidents/, adaugat in indexuri
- README lxc110: host corectat pveelite -> pve1 (+ RAM/CPU/storage reale),
  comenzile pct redirectionate spre nodul corect
- README lxc171: tabel cu starea swap pe cele 3 noduri (pveelite are zvol,
  nu zram - nu necesita acelasi fix)

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
2026-07-31 10:14:54 +00:00
Claude Agent
679719c295 docs(cluster): document notification targets + cron stdout rules
- Proxmox default-matcher acum trimite doar la mail-to-root (pve1 smtp
  eliminat din matcher → fix emailuri duble pentru backup/vzdump)
- Adaugat tabel cron jobs per nod cu motivul redirect-ului > /dev/null
- Regula: scripturi cu propriile notificari trebuie sa aiba redirect in
  crontab, altfel cron genereaza email suplimentar de confirmare

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-05-01 05:50:34 +00:00
Claude Agent
1203c24d63 docs(proxmox): document HA, corosync tuning, diagnostic tools and mail relay
Following the 2026-04-20 cluster outage, the cluster README now covers
HA resource limits, corosync token tuning (10s tolerance for USB glitches),
rasdaemon/netconsole/kdump diagnostic stack on pvemini, mail relay via
mail.romfast.ro with SMTP auth, OOM alerting via cron, and swap on pveelite.

VM 109 README now clearly states it was removed from HA and is only
started by the weekly DR test script.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-20 11:30:46 +00:00
Marius
4d51d5b2d2 Reorganize proxmox documentation into subdirectories per LXC/VM
- Create cluster/ for Proxmox cluster infrastructure (SSH guide, HA monitor, UPS)
- Create lxc108-oracle/ for Oracle Database documentation and scripts
- Create vm201-windows/ for Windows 11 VM docs and SSL certificate scripts
- Add SSL certificate monitoring scripts (check-ssl-certificates.ps1, monitor-ssl-certificates.sh)
- Remove archived VM107 references (decommissioned)
- Update all cross-references between files
- Update main README.md with new structure and navigation

Co-Authored-By: Claude Opus 4.5 <noreply@anthropic.com>